Electromagnetic Dosing Pump Common Faults & Troubleshooting

How to Solve Electromagnetic Dosing Pump Common Faults?

Troubles & Solutions

In industrial production and processing, electromagnetic dosing pumps may fail to work properly due to various causes and affect industrial production. We have summarized the reasons and solutions for faults such as the pump cannot be displayed or started, fail to suck liquid, and unstable capacity. This will help you quickly troubleshoot dosing pump problems and better serve industrial production.

Electromagnetic dosing pump head part

Common Faults & TroubleshootingCommon Faults & Troubleshooting

Fault Possible Causes Correction Method
The pump cannot be displayed or started Wiring error Check and correct wiring
Wrong voltage Set the right voltage by nameplate
Circuit board fuse Replace the right safety tube
Circuit board damaged Replace the circuit board
The pump cannot suck liquid. The liquid suction end is not sealed well. Check whether the seals and quick links are in good condition.
Wrong valve assembly Check and reassemble according to the instructions
Suction too high Reduce the installation height of the pump.
Suction pipe blocked Open the exhaust valve to remove gas.
The liquid is too viscous or easily produces bubbles. The installation position is lower than the liquid level.
Foot valve blocked Clean filter plate and foot valve.
Pump head blocked or impurities Clean pump head and components.
Unstable capacity Impurities in pump head Clean pump head and components.
Diaphragm damage Replace diaphragm
Lower capacity Impurities in pump head Clean pump head and components
Outlet pressure is too high Check nameplate and replace dosing pump with higher pressure.
Liquid viscosity is too high. Please contact the manufacturer, change high viscosity check valve if necessary.
Driven unit damaged (electromagnet) Return to factory for replacement.
Circuit board damaged Replace the circuit board.
Larger capacity Siphon occurs Set a back pressure valve onto the liquid outlet pipe.
Small outlet pressure Set a back pressure onto the outlet pipe or change one smaller capacity pump.
Liquid leakage Upper and lower valve nuts loose Tighten nuts.
Pump head becomes loose Tighten bolts.
M/HX: 2.16 N.m
NX/GX: 2.41 N.m
30L/50L: 2.90 N.m
Diaphragm damage Replace diaphragm
Seal part missing Replace the seal part.
Seal parts or pump head is corroded. Please contact the manufacturer.
The outside temperature or liquid temperature is too high. Please contact the manufacturer

If your electromagnetic dosing pump has the above faults during use, please refer to our troubleshooting solutions. If you encounter problems that cannot be solved, please feel free to contact us, we will help you and ensure that the dosing pump can be put into operation again.