During metering and conveying in industrial production and processing, Motor-X dosing pump may cannot work normally due to some reasons and affect industrial production. We have summarized the reasons and solutions for faults such as the mechanical dosing pump cannot be displayed or started, fail to suck liquid, and unstable capacity. This will help you quickly troubleshoot dosing pump problems and better serve industrial production.
Fault | Possible Causes | Correction Method |
---|---|---|
Pump cannot displayed or started. | Wiring error | Check and correct wiring |
Wrong voltage | Set the right voltage by nameplate | |
On/off button damaged | Replace the button. | |
Pump cannot suck liquid. | The liquid suction end is not sealed well. | Check whether the seals and quick links are in good condition. |
Wrong valve assembly | Check and reassemble the valve according to the instructions. | |
Suction too high | Reduce the installation height of the pump. | |
Suction pipe blocked. | Open the exhaust valve to remove gas. | |
The liquid is too viscous or easily produces bubbles. | The installation position is lower than the liquid level. | |
Foot valve blocked. | Clean filter plate and foot valve. | |
Pump head blocked or impurities | Clean pump head and components | |
Unstable capacity | Impurities in pump head | Clean pump head and components. |
Diaphragm damage | Replace diaphragm | |
Lower capacity | Impurities in pump head | Clean pump head and components |
Outlet pressure is too high | Check nameplate and replace dosing pump with higher pressure. | |
Liquid viscosity is too high. | Please contact the manufacturer, change high viscosity check valve if necessary. | |
Driven unit damaged | Return to factory for replacement. | |
Larger capacity | Small outlet pressure | Set a back pressure onto the outlet pipe or change one smaller capacity pump. |
Liquid leakage | Upper and lower valve nuts loose | Tighten nuts. |
Pump head becomes loose | Tighten bolts. M/HX: 2.16 N.m | |
Diaphragm damage | Replace diaphragm | |
Seal part missing | Replace the seal part. | |
Seal parts or pump head is corroded. | Please contact the manufacturer. | |
The outside temperature or liquid temperature is too high. | Please contact the manufacturer |
If your Motor-X dosing pump has the above faults during use, please refer to our troubleshooting solutions. If you encounter problems that cannot be solved, please feel free to contact us, we will help you and ensure that the dosing pump can be put into operation again.