4 types of electromagnetic solenoid dosing pumps are displayed.

Electromagnetic Solenoid Dosing Pumps – Accurate Dosing & Easy to Adjust

Electromagnetic solenoid dosing pump is a type of dosing pump designed to deliver low-flow, low-pressure liquid in pipelines. It is driven by an electromagnetic and is considered one of the most popular and typical products among dosing pumps. Its design principle is "simple and practical," which means it has a simple structure, low energy consumption, accurate metering, and convenient adjustment, making it very popular in the industry. Reasonable and flexible internal design makes customization possible. We can provide solutions for you according to user needs and special working conditions to avoid the embarrassing modification of process design upon the unsuitability of product.

  • Specification
  • Working Principle
  • Videos
Specification
  • A set of DFD type electromagnetic solenoid dosing pump

    DFD manual operation dosing pumps

  • A set of DP type electromagnetic solenoid dosing pump

    DP manual & pulse operation dosing pumps

  • A set of DM type electromagnetic solenoid dosing pump

    DM manual & current signal dosing pumps

  • A set of DC type electromagnetic solenoid dosing pump

    DC manual & RS485 communication protocol dosing pumps

DFD Manual Operation Type

  • Quick and simplified manual operation mode
  • Buttons are used to control start and stop of the pump and set the stroke frequency (spm); setting range of stroke frequency is from 1(spm) to the maximum frequency value; whenever the pump is running or stops, the flow can be adjusted.
  • Flow range is 1–55 L/H, maximum pressure is 20 bar.
  • 5 flow stages are optional that is more accurate and controllable.
  • Current working frequency is digitally displayed.
  • Could be equipped with a liquid level switch interface.
A set of DFD type electromagnetic solenoid dosing pump

Installation Dimensional Drawing

DFD electromagnetic solenoid dosing pump installation dimensional drawing
DFD electromagnetic solenoid dosing pump installation dimensional drawing
DFD electromagnetic solenoid dosing pump installation dimensional drawing
DFD electromagnetic solenoid dosing pump installation dimensional drawing

Technical Specifications

Table 1: DFD Manual Operation Type
DFD Manual Operation Type Model Capacity (L/h) Pressure (bar) Frequency (times/min) Suction (m) Power (w) Weight (kg) Size
DFD-M DFD-01-07-M 1 7 120 2 30 2.1 A
DFD-02-07-M 2 7 120 2 30 2.1 A
DFD-03-07-M 3 7 120 2 30 2.1 A
DFD-06-05-M 6 5 180 2 40 2.1 A
DFD-09-03-M 9 3 180 2 40 2.1 A
DFD-HX DFD-02-20-HX 2 20 180 2 40 2.4 A
DFD-05-12-HX 5 12 180 2 40 2.4 A
DFD-06-07-HX 6 7 180 2 40 2.4 A
DFD-10-05-HX 10 5 200 2 40 2.4 A
DFD-NX DFD-09-07-NX 9 7 160 2 40 3.2 B
DFD-12-07-NX 12 7 160 2 40 3.2 B
DFD-15-04-NX 15 4 200 2 40 3.2 B
DFD-20-03-NX 20 3 200 2 40 3.2 B
DFD-25-02-NX 25 2 200 2 40 3.2 B
DFD-GX DFD-06-16-GX 6 16 200 2 60 3.8 C
DFD-10-10-GX 10 10 200 2 60 3.8 C
DFD-23-05-GX 23 5 200 2 60 3.8 C
DFD-33-03-GX 33 3 200 2 60 3.8 C
DFD-55-0.1-GX 55 0.1 240 2 60 3.8 C
DFD-X DFD-02-16-X 2 16 120 2 65 3.8 C
DFD-06-07-X 6 7 120 2 65 3.8 C
DFD-09-07-X 9 7 120 2 65 3.8 C
DFD-12-07-X 12 7 120 2 65 3.8 C
DFD-15-03-X 15 3 120 2 65 3.8 C
DFD-20-03-X 20 3 160 2 65 3.8 C
DFD-30-03-X 30 3 160 2 65 3.8 D
DFD-50-02-X 50 2 240 2 65 3.8 D
Notes: 220V 50Hz power supply is optional for all models except DFD-10-16-GX, and 220V 60Hz power supply is also optional for DFD-M, DFD-GX and DFD-X.

DP Manual & Pulse Operation Type

  • Manual operation control mode: adjusted by Up and Down buttons, whenever the pump is running or stops, the stroke frequency of the pump can be adjusted by control button.
  • Pulse signal control mode: a remote automatic control mode and frequency division mode and frequency multiplication mode are optional to adjust the proportional dosing and further control the stroke frequency of the pump.
  • Current working frequency is digitally displayed.
  • Equipped with a liquid level switch interface.
A set of DP type electromagnetic solenoid dosing pump

Installation Dimensional Drawing

DP electromagnetic solenoid dosing pump installation dimensional drawing
DP electromagnetic solenoid dosing pump installation dimensional drawing
DP electromagnetic solenoid dosing pump installation dimensional drawing

Technical Specifications

Table 2: DP Manual & Pulse Operation Type
DP DP Manual & Pulse Operation Type Model Capacity (L/h) Pressure (bar) Frequency (times/min) Suction (m) Power (w) Weight (kg) Size
DP-LM DP-01-07-LM 1 7 120 2 30 3.2 B
DP-02-07-LM 2 7 120 2 30 3.2 B
DP-03-07-LM 3 7 120 2 30 3.2 B
DP-06-05-LM 6 5 140 2 30 3.2 B
DP-09-03-LM 9 3 160 2 30 3.2 B
DP-X DP-02-16-X 2 16 120 2 65 3.8 C
DP-06-07-X 6 7 120 2 65 3.8 C
DP-09-07-X 9 7 120 2 65 3.8 C
DP-12-07-X 12 7 120 2 65 3.8 C
DP-15-03-X 15 3 120 2 65 3.8 C
DP-20-03-X 20 3 160 2 65 3.8 C
DP-30-03-X 30 3 160 2 65 3.8 D
DP-50-02-X 50 2 240 2 65 3.8 D
DP-GX DP-06-16-GX 6 16 200 2 60 3.8 C
DP-23-05-GX 23 5 200 2 60 3.8 C
DP-33-03-GX 33 3 200 2 60 3.8 C
DP-55-0.1-GX 55 0.1 240 2 60 3.8 C
Note: power supply: 220V 50/60Hz

DM Manual & Current Signal Type

  • Manual operation control mode: adjusted by Up and Down buttons, whenever the pump is running or stops, the stroke frequency of the pump can be adjusted by control button.
  • Current signal control mode: a remote control method with analogue signals, and the stroke frequency (spm) can be set proportionally controlled within 4–20 mA.
  • Current working frequency is digitally displayed.
  • Equipped with a liquid level switch interface.
A set of DM electromagnetic solenoid dosing pump

Installation Dimensional Drawing

DM electromagnetic solenoid dosing pump installation dimensional drawing
DM electromagnetic solenoid dosing pump installation dimensional drawing
DM electromagnetic solenoid dosing pump installation dimensional drawing

Technical Specifications

Table 3: DM Manual & Current Signal Type
DM Manual & Current Signal Type Model Capacity (L/h) Pressure (bar) Frequency (times/min) Suction (m) Power (w) Weight (kg) Size
DM-LM DM-01-07-LM 1 7 120 2 30 3.2 B
DM-02-07-LM 2 7 120 2 30 3.2 B
DM-03-07-LM 3 7 120 2 30 3.2 B
DM-06-05-LM 6 5 140 2 30 3.2 B
DM-09-03-LM 9 3 160 2 30 3.2 B
DM-X DM-02-16-X 2 16 120 2 65 3.8 C
DM-06-07-X 6 7 120 2 65 3.8 C
DM-09-07-X 9 7 120 2 65 3.8 C
DM-12-07-X 12 7 120 2 65 3.8 C
DM-15-03-X 15 3 120 2 65 3.8 C
DM-20-03-X 20 3 160 2 65 3.8 C
DM-30-03-X 30 3 160 2 65 3.8 D
DM-50-02-X 50 2 240 2 65 3.8 D
DM-GX DM-06-16-GX 6 16 200 2 60 3.8 C
DM-23-05-GX 23 5 200 2 60 3.8 C
DM-33-03-GX 33 3 200 2 60 3.8 C
DM-55-0.1-GX 55 0.1 240 2 60 3.8 C
Note: power supply: 220V 50/60Hz

DC Manual & RS485 Communication Protocol Type

  • Manual operation control mode: adjusted by Up and Down buttons, whenever the pump is running or stops, the stroke frequency of the pump can be adjusted by control button.
  • RS485: intelligent automatic control mode, a standard serial communication protocol, can communicate with the upper computer to achieve online control of the pump start and stop and stroke frequency.
  • Current working frequency is digitally displayed.
  • Equipped with a liquid level switch interface.
DC electromagnetic solenoid dosing pump

Installation Dimensional Drawing

DC electromagnetic solenoid dosing pump installation dimensional drawing
DC electromagnetic solenoid dosing pump installation dimensional drawing

Technical Specifications

Table 4: DC Manual & RS485 Communication Protocol Type
DC Manual & RS485 Communication Protocol Type Model Capacity (L/h) Pressure (bar) Frequency (times/min) Suction (m) Power (w) Weight (kg) Size
DC-L DC-01-07-L 1 7 120 2 30 3.8 C
DC-02-07-L 2 7 120 2 30 3.8 C
DC-03-07-L 3 7 120 2 30 3.8 C
DC-06-05-L 6 5 140 2 30 3.8 C
DC-09-03-L 9 3 160 2 30 3.8 C
DC-X DC-02-16-X 2 16 120 2 65 3.8 C
DC-06-07-X 6 7 120 2 65 3.8 C
DC-09-07-X 9 7 120 2 65 3.8 C
DC-12-07-X 12 7 120 2 65 3.8 C
DC-15-03-X 15 3 120 2 65 3.8 C
DC-20-03-X 20 3 160 2 65 3.8 C
DC-30-03-X 30 3 160 2 65 3.8 D
DC-50-02-X 50 2 240 2 65 3.8 D
DC-GX DC-06-16-GX 6 16 200 2 60 3.8 C
DC-23-05-GX 23 5 200 2 60 3.8 C
DC-33-03-GX 33 3 200 2 60 3.8 C
DC-55-0.1-GX 55 0.1 240 2 60 3.8 C
Note: power supply: 220V 50/60Hz
Working Principle

The electromagnetic push rod of the electromagnet is provided with a PTFE diagram. When the electromagnet is energized, the electromagnetic push rod pushes the PTFE diaphragm to discharge the liquid in the pump head of the dosing pump out of the dosing pump through the outlet valve. Then the electromagnet is curt off. The electromagnetic push rod and PTFE diaphragm return under the action of the spring. The liquid is sucked into the dosing pump through the inlet valve of the dosing pump to complete a working cycle.

The working principle of electromagnetic solenoid dosing pump
Videos
Downloads

Here are product catalogue and data sheet for your reference. more information just contact us.

The nuonuo is answering the phone.