Generally, every chemical cleaning takes 6 hours. The time it takes depends on the circulating and soaking period as well as the time for cleaning agent and equipment preparation. Online measure the permeability of UF membrane before and after every chemical cleaning method to evaluate the cleaning effect.
Contaminant Types & Cleaning Agent Selection
You may refer to the table below to help you choose the cleaning agent, bactericide type and concentration.
Contaminant | Cleaning Agent & Bactericide | Cleaning Agent Concentration |
---|---|---|
Bacteria, organics | Sodium hypochlorite | 500 ppm (active chlorine) |
Organics, silicon oxide | Sodium hydroxide | 5% below |
Organics | Nitric acid, hydrochloric acid, sulfuric acid | 5% below |
Oxalic acid | 2% below | |
Citric acid | 5% below | |
EDTA | 0.4% below | |
Bacteria | Sodium hypochlorite | 10–100 ppm |
Outside-In UF Membrane Cleaning Scheme
Solution | Range of Application | Cleaning Scheme |
---|---|---|
Alkaline cleaning solution | Organic fouling |
|
Sodium hypochlorite cleaning solution | UF membrane fouling caused by organics and living organisms |
|
Acid cleaning solution | Inorganic fouling (iron fouling and carbonate crystal fouling) |
|
Inside-Out UF Membrane Cleaning Scheme
Solution | Range of Application | Cleaning Scheme |
---|---|---|
Alkaline cleaning solution | Organic fouling |
|
Acid cleaning solution | Inorganic fouling (such as iron) |
|