Troubleshooting
Troubles | Reasons | Solutions |
---|---|---|
High trans-membrane pressure drop | Fouled UF membrane elements | Find out the cause of contamination, take proper cleaning measures and adjust the flushing parameters. |
High permeate flow | Adjust the flow according to the requirements stated in the operation guide. | |
Low feed water temperature | Improve the feed water temperature. | |
Small permeate flow | Fouled UF membrane elements | Find out the cause of contamination, take proper cleaning measures and adjust the flushing parameters. |
Incorrect valve opening setting | Check and ensure all valve that should be open are open and adjust the valve opening. | |
Flow meter is out of work. | Check the flow meter and ensure it can work smoothly. | |
Low feed pressure | Verify and solve this problem. | |
Low feed water temperature | Improve the feed water temperature and pressure. | |
Poor permeate quality | Unqualified feed water quality | Check the feed water quality, especially turbidity and COD. |
Damaged membrane elements | Find out the cause of damage and replace the membrane element. | |
The system fails to run automatically. | The feed pump fails to start. | Exclude the possibility of incorrect wiring. Convert the pump into manual mode and restart it and then change it to automatic control after normal operation. |
High feed water pressure | Check the feed pump; Adjust the pressure switch. | |
High permeate back pressure | The permeate outlet valve is closed; The subsequent system fails to start promptly; Adjust the pressure switch. | |
PLC program error | Check the program. |