2 different types of level instruments

Level Instrument – Measurement and Monitoring of Material Height

Level instrument is a device used to measure and monitor the height or volume of liquid, slurry or solid materials in containers, tanks or silos. It is widely used in industrial process control, storage management and environmental monitoring. Level instrument ensures the continuity, safety and efficiency of the production process by accurately measuring and monitoring the material height.

  • Specification
  • Video
Specification
  • A MP ultrasonic level transmitter

    SUP-MP Ultrasonic Level Transmitter

  • A ULS-B ultrasonic level transmitter

    SUP-ULS-B Ultrasonic Level Transmitter

  • A submersible level sensor

    SUP-P261 Submersible Level Sensor

  • A submersible level sensor

    SUP-P260 Submersible Level Sensor

  • 2 RD701 radar level meter

    SUP-RD701 Radar Level Meter

  • A RD902 radar level meter

    SUP-RD902 Radar Level Meter

  • A RD902T radar level meter

    SUP-RD902T Radar Level Meter

  • A RD903 radar level meter

    SUP-RD903 Radar Level Meter

  • A RD908 radar level meter

    SUP-RD908 Radar Level Meter

  • A RD1000 radar level meter

    SUP-RD1000 Radar Level Meter

This ultrasonic level transmitter is a universal one characterized by total digitalized and humanized design. It has perfect level monitoring, data transmission and man-machine communication. The master chip is imported technical single chip with relevant application specific IC like digital temperature compensation. It features strong anti-interference performance, free setting of upper and lower limits and online output regulation, on-site indication.

Features

  • Intelligent adjustment response
  • Intelligent double-line display
  • Intelligent adjustable range
  • Processing of special echo
  • All physical closed probe
  • Multi-point emission circuit
A MP ultrasonic level transmitter

Parameters

Table 1: SUP-MP Ultrasonic Level Transmitter Parameters
Measuring range 0–15 m
Accuracy ±0.5% F.S
Temperature drift ±0.01 F.S/°C
Medium temperature -20 °C to +70 °C
Overload pressure 200% F.S
Power supply 14–28V DC
Ambient temperature Converter: -20 °C to +60 °C
Probe: -20 °C to +80 °C
Ingress protection IP65
Signal output 4–20mA RL > 500Ω
Relay output 2 relays (AC: 5A 250V, DC: 10A 24V)
Communication RS485 (optional)
Installation Thread/flange

Parameters

Table 2: SUP-ULS-B Ultrasonic Level Transmitter Parameters
Measuring range 0–15 m
Accuracy ±0.5% F.S
Temperature drift ±0.01 F.S/°C
Medium temperature -20 °C to +80 °C
Overload pressure 200% F.S
Power supply 100–240V AC, 5W MAX, 50/60 Hz 18–28V DC
Ambient temperature Converter: -20 °C to +60 °C
Probe: -20 °C to +80 °C
Ingress protection Converter: IP65
Senor: IP68
Signal output 4–20mA
Output precision: ±0.5% F.S, RL≤ 500Ω
Relay output 2 relays
Communication RS485
Material Engineering plastics
Installation Thread/flange

Parameters

Table 3: SUP-P261 Submersible Level Sensor Parameters
Measuring range 0–200 m
Accuracy 0.5% F.S
Temperature drift ≤0.03 F.S/°C
Medium temperature -10 °C to +65 °C
Overload pressure 150% F.S
Power supply 12–30V DC
Ambient temperature -20 °C to +65 °C
Ingress protection Senor: IP68 2088
Wiring: IP65
Signal output 4–20mA, 1–5V, 0–10mA, 0–20mA, 1–5V
Relay output
Communication RS485 (optional)
Installation

It utilizes the piezoresistive effect of diffusion silicon to transform pressure into electrical signal. After temperature compensation and linear correction, it is converted to 4–20mA standard current signal and output. It is easy to install and measures accurately. It is widely used in liquid level measurement of various medium in petrochemical metallurgy, power, pharmaceutical, water supply and drainage, environmental protection and other industries.

Features

  • Easy installation, easy to use, strong interchangeability
  • Corrosion resistance, power supply is not required
  • Good sealing performance, high reliability, safe use
  • The high quality sensor with high sensitivity and fast response
  • Wide measurement range, free from the limit of height of storage tank
  • Strong anti-interference capability
  • The anti blocking design can realize the measurement of the level of paste medium
  • Various measured medium, not affected by the foaming or deposition of the medium
A submersible level sensor

Parameters

Table 4: SUP-P260 Submersible Level Sensor Parameters
Power supply 12–30V DC Zero temperature drift ±0.3% FS/10 °C(-10 to +70 °C)
Signal output 4–20mA, 1–5V, 0–5V, RS485 Overload pressure 150% F.S
Range 0–100 m Long-term stability ≤ 0.2% F.S/year
Accuracy 0.3%/0.5% optional Measuring medium Liquid
Non-linearity ≤ 0.5% F.S Diaphragm material 316L stainless steel
Medium temperature -20 to +60 °C Body material SS304 or SS316L
Environment temperature -10 to +125 °C Ingress protection IP68
Temperature compensation -10 to +70 °C

Parameters

Table 5: SUP-RD701 Radar Level Meter Parameters
Range 0–30 m
Accuracy ±10 mm
Temperature drift
Frequency 500MHz – 1.8GHz
Medium temperature -40 °C to +250 °C
Power supply Two-wire: 24V DC
Four-wire: 24V DC/220V AC
Environment temperature -40 °C to +250 °C
Ingress protection IP67
Output signal 4–20mA
Relay output
Communication RS485
Material Shell: aluminum/plastic
Process connection Thread/flange

Parameters

Table 6: SUP-RD902 Radar Level Meter Parameters
Range 0–30 m
Accuracy ±5–15 mm
Temperature drift
Frequency 26GHz
Medium temperature -40 °C to +250 °C
Power supply Two-wire: 24V DC
Four-wire: 6–24V DC
Environment temperature -20 °C to +80 °C
Ingress protection IP67
Output signal 4–20mA
Relay output
Communication RS485
Material Aluminum
Process connection Thread/flange

Parameters

Table 7: SUP-RD902T Radar Level Meter Parameters
Range 0–20 m
Accuracy ±10 mm
Temperature drift
Frequency 26GHz
Medium temperature Standard type: -40 °C to +250 °C
High temperature type: -40 °C to +230 °C
Power supply Two-wire: 24V DC
Four-wire: 6–24V DC
Environment temperature -20 °C to +80 °C
Ingress protection IP67
Output signal 4–20mA
Relay output
Communication RS485
Material Aluminum
Process connection Thread/flange

Parameters

Table 8: SUP-RD903 Radar Level Meter Parameters
Range 0–70 m
Accuracy ±20–30 mm
Temperature drift
Frequency 26GHz
Medium temperature -40 °C to +250 °C
Power supply Two-wire: 24V DC
Four-wire: 6–24V DC
Environment temperature -20 °C to +80 °C
Ingress protection IP67
Output signal 4–20mA
Relay output
Communication RS485
Material Aluminum
Process connection Thread/flange

Parameters

Table 9: SUP-RD908 Radar Level Meter Parameters
Range 0–30 m
Accuracy ±5–10 mm
Temperature drift
Frequency 26GHz
Medium temperature -40 °C to +100 °C
Power supply Two-wire: 24V DC
Four-wire: 6–24V DC
Environment temperature -40 °C to +70 °C
Ingress protection IP67/IP65
Output signal 4–20mA
Relay output
Communication RS485
Material Aluminum/plastic
Process connection Thread/flange

Parameters

Table 10: SUP-RD1000 Radar Level Meter Parameters
Range 5–20 m
Accuracy 0.1% F.S
Temperature drift
Frequency 80GHz
Medium temperature -30 °C to +150 °C
Power supply DC 24V (22V–30V)
Environment temperature -20 °C to +70 °C
Ingress protection IP66
Output signal 4–20mA
Relay output
Communication RS485
Material
Process connection Thread/flange