Daily
Measurement Range | 3 m (The longer can be customized) | |
---|---|---|
Dead Zone | 0.3 m (can be customized) | |
Resolution | 0.001 m | |
Accuracy | ±0.3% × FS or ±2 mm (max) | |
Display | 4 LED | |
Transmitting Output | No.of channel | Single channel (4–20)mA |
Loop resistance | RL > 600 Ω | |
Communication Port | RS485 (Modbus protol) | |
Control Output | No.of Channel | Double channels |
Electrical contact | Semiconductor photoelectric relay 50mA (Max.), AC/DC 30V | |
Working Power Source | Power supply | DC (12–24)V |
Power Consumption | ≤ 1.5W | |
Working Environment | Temperature: (0–50) °C Relative Humidity: ≤ 85% RH (none condensation) |
|
Storage Environment | Temperature: (-40 to +85) °C Relative Humidity: ≤ 85% RH (none condensation) |
|
Protection | IP65 | |
Dimension Size | 90 mm × 200 mm × (M60) | |
Installation Method | Installation hole M60 × 2 |
It widely used in liquid level measurement and material-level in the oil, paper, mining, power plants, chemical industry, water treatment plants, waste water purification, pharmaceutical, agricultural pumping, environmental monitoring, sewage treatment and other fields.
Here are product catalogue and data sheet for your reference. more information just contact us.