Reverse osmosis controller is a device used to monitor and control the operation of reverse osmosis systems. It has functions such as monitoring and displaying key parameters, controlling system operation, abnormal condition alarms, data recording and communication. It is widely used in water treatment and industrial applications of reverse osmosis systems to ensure the stable operation of the system and the compliance of water quality.
ROC-2015 Single Stage RO Controller
ROC-2315 Single Stage Single Channel RO Controller
ROC-8221 Single Stage Double Channels RO Controller
Small size and simple single stage integration reverse osmosis control system.
Main Technical Data
Single Detection | Dry contact input | Dry-run protection function |
---|---|---|
Low-pressure protection function | ||
High-pressure protection function | ||
Water level limit | ||
High-pressure and low-pressure flushing function |
||
Control Port | Dry contact output | Water feeding solenoid valve |
RO flushing solenoid valve | ||
Booster pump | ||
Low-pressure water pump | ||
Power Supply | AC 220V(±10%), 50/60Hz | |
Working Environment | Temperature: (0–50) °C Relative Humidity: ≤ 85% RH (no condensation) |
|
Dimension (H × W × D) | 48 mm × 96 mm × 80 mm | |
Hole Size (H × W) | 44 mm × 92mm | |
Installation | Panel mounted, fast installation | |
Certification | CE |
Single stage RO controller used for conductivity monitoring and process program control.
Main Technical Data
Signal Detection (six channels) | Dry contact input | Raw water no water protection | |
---|---|---|---|
Low pressure protection | |||
High pressure protection | |||
Pure water tank high level | |||
External control mode signal | |||
Running reset | |||
Control Port (five channels) | Dry contact output | Raw water pump | SPST-NO Load.capacity AC 220V/3A Max AC 110V/5A Max |
Inlet valve | |||
High pressure pump | |||
Flush valve | |||
Conductivity over-limit drainage valve | |||
Measurement Detection Point | Product water conductivity | ||
Measurement Range (ROC-2315) | Product water conductivity: 0.1–200 μS/cm, 1–2000 μS/cm or 10–999 μS/cm (with different sensor) Product water Temp.: 0–50 °C |
||
Temp. Compensation | Automatic compensation, with 25 °C as the reference temperature | ||
Accuracy | 1.5% (FS) | ||
Working Environment | Temp.: (0–50) °C Relative Humidity: ≤ 85% RH (none condensation) |
||
Storage Environment | Temp.: (-20 to +60) °C Relative Humidity: ≤85% RH (none condensation) |
||
Power Supply | AC 220V (±10%) 50/60 Hz | ||
Dimension (H × W × D) | 96 mm × 96 mm × 130 mm | ||
Hole Size (H × W) | 91 mm × 91 mm | ||
Installation | Panel mounted, fast installation |
Singe stage double channels integration RO controller used for conductivity monitoring and process program control.
Main Technical Data
Signal Detection (seven channels) | Dry contact input | Raw water tank level: double channels | Low level |
---|---|---|---|
High level | |||
Pure water tank level: double channels | Low level | ||
High level | |||
Low pressure protection | |||
High pressure protection | |||
Pre treatment backwash signal | |||
Control Port (five channels) | Dry Contact Output | Raw water pump | SPST-NO Load capacity AC 220V/3A Max AC 110V/5A Max DC 24V/3A Max |
Inlet valve | |||
High pressure pump | |||
Flush valve | |||
Conductivity over-limit drain valve | |||
Measure Detection Points |
Raw water conductivity, product water conductivity, raw water Temp. | ||
Conductivity Measurement Range | Raw water conductivity | Cell constant: 10.0 cm-1 | (0–20000) uS/cm |
Cell constant: 1.0 cm-1 | (0–2000) μS/cm | ||
Product water conductivity | Cell constant: 1.0 cm-1 | (0–2000) μS/cm | |
Cell constant: 0.1 cm-1 | (0–200) μS/cm | ||
Medium Temp. | 0–50 °C | ||
Accuracy | 1.5% (FS) | ||
Communication | RS 485 communication (Modbus protocol) | ||
Working Environment | Temp.: (0–50) °C Relative Humidity: ≤ 85% RH (none condensation) |
||
Storage Environment | Temp.: (-20 to +60) °C Relative Humidity: ≤ 85% RH (none condensation) |
||
Power Supply | DC 24V±4V | ||
Protection Level | IP65 (with back cover) | ||
Dimension (H × W × D) | 130 mm × 180 mm × 60 mm | ||
Hole Size (H × W) | 122 mm × 172 mm | ||
Installation | Panel mounted, fast installation |
Dry Run Protection: When the raw water supply is interrupted, to prevent the system from running idle, the controller will activate the dry run protection function. If the water supply pressure or level returns to normal, the controller will restart the RO system operation.
Low Pressure Protection: When the current stage pre-filter system is in the flushing, regeneration, or the security filter is clogged, it cannot provide normal water supply pressure to the RO system (i.e., low pressure is insufficient), the controller temporarily shuts down the entire RO system. After the pressure recovers for 1 minute, the RO control system will perform the first trial startup and run the RO system.
High Pressure Protection: When the system experiences overpressure, the controller proactively shuts down the entire RO system. After the high pressure is eliminated for 1 minute, the controller will perform the first trial run.
Pure water tank level control: When the pure water tank level is at the preset low level, the controller immediately starts the RO system to produce water. The system continues until the pure water tank level reaches the predetermined high level, at which point the system completes the membrane flushing and automatically switches to standby mode.
Timed membrane flushing: When the protection device and the operating status are normal, the system will perform the first membrane flushing each time it is powered on. Subsequently, membrane flushing occurs each time the low water production is activated, and after the production tank is full, the system automatically completes membrane flushing.
Here are product catalogue and data sheet for your reference. more information just contact us.