Brass/Stainless Steel Male Connection
 

SVF EV series plastic tube variable-area flow meter is a variable area flow meter, its main material is polycarbonate (PC) or polysulfone (PSU), so it has excellent high temperature resistance and corrosion resistance. The unique spring design allows the flowmeter to be placed at any angle without affecting accuracy, and the red flow card label is easy to use and identify, making it the most readable flow meter among similar products.
| Model | Measurement Range | Operating Pressure (MPa) | Operating temperature (°C) | Accuracy (±%) | Interface Thread | Interface Material | |||
|---|---|---|---|---|---|---|---|---|---|
| 20 °C Water | 20 °C Air: 101325 Pa | ||||||||
| GPM | LPM | GPM | LPS | ||||||
| SF EV15 SF EV20 SF EV25 | 0.5–5 1–7 1–10 1–16 3–18 4–28 | 2–20 4–26 4–35 5–60 15–65 20–100 | 80–320 160–480 240–720 320–1100 | 5–20 10–30 15–45 20–70 | ≤1 | Polycarbonate: 0–80 °C Polysulfone: 0–120 °C | ±6 | ZG, Z, G 1/2" (Female, Male) ZG, Z, G 3/4" (Female, Male) ZG, Z, G 1" (Female, Male) | Brass Stainless Steel PP PVC | 
| SF EV40 SF EV50 | 3–25 5–50 8–80 10–100 | 12–90 20–200 30–280 40–380 | 250–1500 350–2200 450–4500 | 15–95 20–140 25–275 | ZG, Z, G 1 1/2" (Female) ZG, Z, G 2" (Female) 2" Plastic Pipe Socket Connection | ||||
Dimensions

Brass/Stainless Steel Male Connection

PP/PVC Female Connection

Brass/Stainless Steel Female Connection