Four different types runxin continuous water supply control valve.

Runxin Continuous Water Supply Control Valves Improve Softening Working Efficiency

To satisfy markets continuous water supply requirements, Runxin develop Runxin continuous water supply Control Valves, which can control two tanks one time to achieve one in service and one standby and guarantee continuous water supply.

This system contains one control valve and two tanks, it can achieve downflow or upflow regeneration through switch program. Besides, it adopts top or side mount method according to different output and tank structure..

  • Specification
  • Video
Specification
  • A set of runxin one valve on duplex tank continuous water supply control valve.

    One in Service One Standby – One Valve on Duplex Tank

  • A set of runxin floating bed one valve on duplex tank continuous water supply control valve.

    One in Service One Standby – Floating Bed

  • A set of runxin two valve on duplex tank continuous water supply control valve.

    One in Service One Standby – Two Valve and Two Tank

  • A set of runxin control valve for two in service and one standby softening.

    Two in Service One Standby

Table 1: Popular Models & Data Sheet of One Valve on Duplex Tank Control Valves
Model 17603 (F73) 17606 (F98A) 17606T (F137) 17610 (F88A) 17610T (F135A)
Water Capacity 3.5 m3/h 6 m3/h 6 m3/h 10 m3/h 10 m3/h
Running Model Meter Meter Meter Meter Meter
Regeneration Type Upflow/Downflow Upflow Downflow Upflow Downflow
Mount Type Top Mount Side Mount Top Mount Side Mount Top Mount
Inlet/Outlet 1"M 1"M 1"M 1.5"M 1.5"M
Drain 1/2"M 3/4"M 3/4"M 1"M 3/4"M
Brine Tank Connector 3/8"M 1/2"M 1/2"M 1/2"M 1/2"M
Base 2.5"-8NPSM - 4"-8UN - 4"-8UN
Riser Pipe 1.05" O.D. Side mount, top and bottom distributor 1"M 1.5"D-GB or 1.9" O.D. Side mount, top and bottom distributor 1.5"M 1.5"D-GB or 1.9" O.D.
Available Tank Size 12"–14" 20"–21" 16"–24" 20"–30" 20"–30"
Turbidity < 2 FTU or < 5 FTU < 2 FTU < 5 FTU < 2 FTU < 5 FTU
Table 1: Popular Models & Data Sheet of Floating Bed Control Valves
Model 93606 (F98C) 93610 (F88C)
Water Capacity 6 m3/h 10 m3/h
Running Model Meter Meter
Regeneration Type Upflow Upflow
Mount Type Side Mount Side Mount
Inlet/Outlet 1"M 1.5"M
Drain 3/4"M 1"M
Brine Tank Connector 1/2"M 1/2"M
Base - -
Riser Pipe Side mount, top and bottom distributor 1"M Side mount, top and bottom distributor 1.5"M
Available Tank Size 14"–16" 20"–21"
Turbidity < 2 FTU < 2 FTU
A set of runxin floating bed one valve on duplex tank continuous water supply control valve.

5–6 m3/h

  • Suitable for 5-6 m3/h Continuous Water Supplying
  • Two F92A3/F130A3 and DN25 Three-way Electronic Bal Valve (Four Core Plug)
  • Two F92A3/F130A3 are interlocked as one system, and set C-02 (a connection for one in service one standby softening system)
A set of runxin floating bed one valve on duplex tank continuous water supply control valve.

10–20 m3/h

  • Suitable for 10-20 m3/h Continuous Water Supplying
  • Two N74A3/F99A3/N77A3/F95A3/F111A3 and F80
  • Two valves are interlocked as one system, and set the system to A-02 and b-01; Connect the signal output connector with the control wire of F80.
  • When the flow of working valve reduces to 0, the control valve regenerates F80 switches by the signal outlet connector controlling, the other valve turns to service.
  • If the other valve is in regeneration, because of the function of interlock, the working valve still in service.
A set of runxin floating bed one valve on duplex tank continuous water supply control valve.

40–50 m3/h

  • Suitable for 40–50 m3/h Continuous Water Supplying
  • Two F112A3/F96A3 and Two DN25 Electronic Ball Valves
  • Two valves are connected to signal line of one in service and one standby system (interlock wire), and set the system to C-02 (One in Service One Standby System).
  • Ordinary F112A3/F96A3 needs to replace brine draw copper tube and install DN25 ball valve with it.
  • Continuous water supplying, one valve in service, the other valve standby.
A set of runxin control valve for two in service and one standby softening.
  • One valve controls three tanks, two tanks supply with softened water in series, the other tank standby to achieve water supply continuously.
  • When service finishes, the first grade in series tums to regenerate, the second grade tums to the first grade and supplies with softened water together with the standby tank as the second grade in series, which greatly improves the resin efficiency, saves water and salt.
  • Regeneration tank keeps standby after switch and starts fast rinse before service.
  • Only need one brine tank.
  • It adopts hermetic head faces structure with ceramic sealing, reliable and duration.
  • Up-flow or down-flow regeneration is optional by program.
  • Raw water or softened water for regeneration is optional by changing the moving disk.
  • Remove one tank to make the system as one in service one standby system.
  • There is always two tanks in service in series which could treat the raw water with high hardness. It has backwash function, which could be used in high turbidity application which floating bed system can' t be used.
  • Suitable for treat high hardness water and continuous water supplying application
Table 1: Popular Models & Data Sheet of Two in Service One Standby System
Model 18604A (F118A) 18601B (F120B)
18604B (F118B)
Water Capacity 4 m3/h 1.5 m3/h
Running Model Meter Meter
Regeneration Type Downflow/Upflow Downflow/Upflow
Mount Type Top Mount Top Mount
Inlet/Outlet G1" G3/4"
Drain NPT3/4" NPT3/4"
Brine Tank Connector G3/8" G3/8"
Base 3 × 2.5"-8NPSM 3 × 2.5"-8NPSM
Riser Pipe 3 × 1.05" O.D. 3 × 1.05" O.D.
Available Tank Size 10"–18" 10"–12"
Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa
Water Temperature 5–50 °C 5–50 °C
Turbidity Downflow < 5 FTU
Upflow < 2 FTU
Downflow < 5 FTU
Upflow < 2 FTU
Input Charge AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz
Transformer Output DC 12V/2A DC 12V/2A
Note: F118A raw water regeneration mode; F118B soft water regeneration mode.

Notes:

  • First grade Na refers to First grade NA ion exchanger, second grade Na refers to second Na+ ion exchanger.
  • When the turbidity exceeds the working condition, a filter should be installed on the inlet of control valves.
  • When the water hardness exceeds the working condition, the hardness of treated water can not meet the needed requirements (for example 0.03 mmol/L for boil water), you should adopt secondary softening.
Videos
Downloads

Here are product catalogue and data sheet for your reference. more information just contact us.