Three different types of Runxin automatic filter valve.

Runxin Automatic Filter Valves Achieve Intelligent & Efficient Filter

Compared with the manual filter control valve which needs manually switch station, the Runxin automatic filter control valve can realize automatic station switching, filtering, backwashing and washing functions by setting time or flow parameters, and does not need labor waiting and improves the work efficiency.

The automatic filter valve defaults to the LED display and some models have an optional LCD screen.

The water capacity of 4-50 m3/h can better match the different needs of customers.

  • Specification
  • Working Process
  • Features
  • Video
Specification
Read MoreRead Less
Table 1: Popular Models & Data Sheet of Runxin Automatic Filter Valves
Model Water Capacity Running Model Mount Type Inlet/Outlet Drain Base Riser Pipe Available Tank Size Working Pressure Water Temperature Turbidity Media Input Charge Transformer Output
53502 (F71B1) 2 m3/h Time Clock Top Mount 3/4"M 3/4"M 2.5"-8NPSM 1.05" O.D. 6"–10" 0.15–0.6 MPa 5–50 °C < 20 FTU Sand / Activated Carbon AC 100V – 240V / 50–60 Hz DC 12V/1.5A
53602 (F71B3) Meter
53502B (F71G1) 2 m3/h Time Clock Top Mount 3/4"M 3/4"M 2.5"-8NPSM 1.05" O.D. 6"–10" 0.15–0.6 MPa 5–50 °C < 20 FTU Sand / Activated Carbon AC 100V – 240V / 50–60 Hz DC 12V/1.5A
56603 (F67M) 3 m3/h Meter Top Mount 3/4"M 3/4"M 2.5"-8NPSM 1.05" O.D. 6"–10" 0.15–0.6 MPa 5–50 °C < 20 FTU Sand / Activated Carbon AC 100V – 240V / 50–60 Hz DC 12V/1.5A
53504 (F67C1) 4 m3/h Time Clock Top Mount 1"F 1"F 2.5"-8NPSM 1.05" O.D. 6"–14" 0.15–0.6 MPa 5–50 °C < 20 FTU Sand / Activated Carbon AC 100V – 240V / 50–60 Hz DC 12V/1.5A
53604 (F67C3) Meter
53504S (F67B1) 4 m3/h Time Clock Top Mount 1"F 1"F 2.5"-8NPSM 1.05" O.D. 6"–14" 0.15–0.6 MPa 5–50 °C < 20 FTU Sand / Activated Carbon AC 100V – 240V / 50–60 Hz DC 12V/1.5A
53604S (F67B3) Meter
53504B (F67G1) 4 m3/h Time Clock Top Mount 1"F 1"F 2.5"-8NPSM 1.05" O.D. 6"–14" 0.15–0.6 MPa 5–50 °C < 20 FTU Sand / Activated Carbon AC 100V – 240V / 50–60 Hz DC 12V/1.5A
53504C (F67I1) 4 m3/h Time Clock Top Mount 1"F 1"F 2.5"-8NPSM 1.05" O.D. 6"–14" 0.15–0.6 MPa 5–50 °C < 20 FTU Sand / Activated Carbon AC 100V – 240V / 50–60 Hz DC 12V/1.5A
52504E (F67K) 4 m3/h Time Clock Top Mount 1"M 1/2"M 2.5"-8NPSM 1.05" O.D. 6"–14" 0.15–0.6 MPa 5–50 °C < 20 FTU Sand / Activated Carbon AC 100V – 240V / 50–60 Hz DC 12V/1.5A
53506S (F67B1-A) 4 m3/h Time Clock Top Mount 1"F 1"F 2.5"-8NPSM 1"D-GB 6"–14" 0.15–0.6 MPa 5–50 °C < 20 FTU Sand / Activated Carbon AC 100V – 240V / 50–60 Hz DC 12V/1.5A
53606S (F67B3-A) Meter
53508 (F134A1) 8 m3/h Time Clock Top Mount 1.5"M 1.5"M 4"-8UN 1.25"D-GB or 1.66" O.D. 16"–18" 0.2–0.6 MPa 5–50 °C < 20 FTU Sand / Activated Carbon AC 100V – 240V / 50–60 Hz DC 24V/1.5A
53608 (F134A3) Meter
53510 (N75A1) 10 m3/h Time Clock Top Mount 2"M 2"M 4"-8UN 1.5"D-GB or 1.9" O.D. 6"–21" 0.15–0.6 MPa 5–50 °C < 20 FTU Sand / Activated Carbon AC 100V – 240V / 50–60 Hz DC 24V/1.5A
53610 (N75A3) Meter
53510B (N75B1) 10 m3/h Time Clock Top/Side Mount 2"M 2"M 4"-8UN 1.5"D-GB or 1.9" O.D. 6"–21" 0.15–0.6 MPa 5–50 °C < 20 FTU Sand / Activated Carbon AC 100V – 240V / 50–60 Hz DC 24V/1.5A
53610B (N75B3) Meter
53515 (F99B1) 15 m3/h Time Clock Top/Side Mount 2"M 2"M 4"-8UN 1.5"D-GB or 1.9" O.D. 10"–30" 0.2–0.6 MPa 5–50 °C < 20 FTU Sand / Activated Carbon AC 100V – 240V / 50–60 Hz DC 24V/1.5A
53615 (F99B3) Meter
53518 (N77B1) 18 m3/h Time Clock Top Mount 2"M 2"M 4"-8UN 1.5"D-GB or 1.9" O.D. 30"–36" 0.2–0.6 MPa 5–50 °C < 20 FTU Sand / Activated Carbon AC 100V – 240V / 50–60 Hz DC 24V/1.5A
53520 (F95B1) 21.6 m3/h Time Clock Side Mount 2"M 2"M - Side mount top and bottom distributor 2"M 30"–36" 0.2–0.6 MPa 5–50 °C < 20 FTU Sand / Activated Carbon AC 100V – 240V / 50–60 Hz DC 24V/1.5A
53620 (F95B3) Meter
53520T (F111B1) 20 m3/h Time Clock Top Mount 2"M 2"M 4"-8UN 2"D-GB 30"–36" 0.2–0.6 MPa 5–50 °C < 20 FTU Sand / Activated Carbon AC 100V – 240V / 50–60 Hz DC 24V/1.5A
53620T (F111B3) Meter
53540B (F112B1) 40 m3/h Time Clock Side Mount DN65 DN65 - Side mount, top and bottom distributor DN80 36"–48" 0.2–0.6 MPa 5–50 °C < 20 FTU Sand / Activated Carbon AC 100V – 240V / 50–60 Hz DC 24V/4.0A
53640B (F112B3) Meter
53550 (F96B1) 50 m3/h Time Clock Side Mount DN80 DN80 - Side mount, top and bottom distributor DN100 36"–48" 0.2–0.6 MPa 5–50 °C < 20 FTU Sand / Activated Carbon AC 100V – 240V / 50–60 Hz DC 24V/4.0A
53650 (F96B3) Meter
Working Process
  • Stage 1: RUN (Filter)

    When the system is in running operation, the control panel running status icon lights up. At this time, the raw water enters the control valve from inlet, passes through valve body from the top of valve core, and enters tank through top strainer, and becomes purified water after passing through the filter media layer. The purified water returns to riser pipe via bottom strainer and flows out from outlet.

  • Stage 2: B.WASH (Backwash)

    When the running flow rate is reduced to 0, the system enters regeneration and the main control board controls the motor to drive the terminal large gear to rotate and drive moving disk at the same time The relative positions of moving disk and fixed disk change, causing flow channel to change. After reaching the backwash position, the control panel backwash status icon lights up. Raw water enters the control valve from inlet, enters riser pipe from the upper part of valve core, reaches the lower part of tank, and enters the tank by bottom strainer. Under the action of water flow, the filter media layer is loosened, and the broken activated carbon and intercepted dirt are discharged from drain.

  • Stage 3: WASH

    Backwash ends when backwash time is reduced to 0. The main control board controls the motor rotation to make the relative position of the moving disk and fixed disk change, and flow channel changes again. After reaching the brine slow wash state, the control panel fast rinse status icon lights up. Raw water enters the control valve from the inlet, enters tank from top strainer. It removes impurities caused by the backwash at the bottom tank and returns to riser pipe via bottom strainer and discharges from drain. When the set time is reached, fast rinse ends and then enters the running state.

Three stage of manual filter valve working and it's matched position.
Features
  • Structure and Performance Features
    • LED display, indication of long time power off and data saved after power off (Saved for three days).
    • No hard water bypass in rising cycle.
    • With signal output connector and two modes (b-01 or b-02) are optional.
    • Can set rinsing frequency F-00, realizing one time service and several times of backwash and fast rinse.
    • With remote control connector to recieve passive signals.
    • With interlock connector to realize service simultaneously and rinse one by one.
    • Start rising by days or hours.
    • N77, F95 and F111 have two valve cores, one is for controlling inlet water, the other is for outlet water.
    • Time clock type or meter type is optional.
    • N77/F95 with RS-485 port are optional.
  • Applications
    • Residential Filter System (F71/F67).
    • Activated carbon filter or sand filter system for RO pretreatment system.
Videos
Downloads

Here are product catalogue and data sheet for your reference. more information just contact us.

The nuonuo is answering the phone.
Interested?