Daily
Industrial UV water sterilizers are constructed using high-quality stainless steel materials, capable of resisting corrosion from chemicals, humidity, and high temperatures typically encountered in industrial environments. This ensures the long-term stable operation of the equipment under harsh conditions. The system is equipped with an electrical control box for operating and monitoring the device. The control box features an advanced control system and human-machine interface for real-time monitoring of the sterilizer.
Furthermore, industrial UV water sterilizers undergo salt spray testing to demonstrate excellent corrosion resistance. Salt spray testing is a commonly used method to assess corrosion resistance by exposing the equipment to a saltwater solution and specific environmental conditions to test if the device can withstand long-term use without rusting in harsh environments. Industrial UV water sterilizers undergo 24 hours of salt spray testing. It proves that these machines can maintain excellent corrosion resistance in harsh environments, and are suitable for industrial applications.
SB10 Series
SA Series
SBA Series
SIB Series
SIBM Series
Medium Pressure UV Series
Water Quality Requirements
Specifications
Model | Flow Rate | Reactor Dimension | In/Outlet Port BSP/NPT |
UV Lamp Code | Lamp Power | Quartz Tube Code | Ballast Code | |
---|---|---|---|---|---|---|---|---|
m3/hr | GPM | |||||||
SB10-H02 | 14 | 61 | 1212 × 133 mm | DN65(2.5") | GHO1148T5L/4P | 120 W × 2 | QT5-1183 | ZUM3-800-120 |
SB10-H03 | 27 | 120 | 1212 × 168 mm | DN80(3"') | GHO1148T5L/4P | 120 W × 3 | QT5-1183 | ZUM3-800-120 |
SB10-H04 | 35 | 155 | 1212 × 168 mm | DN100(4") | GHO1148T5L/4P | 120 W × 4 | QT5-1183 | ZUM3-800-120 |
SB10-H05 | 58 | 255 | 1212 × 219 mm | DN100(4") | GHO1148T5L/4P | 120 W × 5 | QT5-1183 | ZUM3-800-120 |
SB10-H06 | 69 | 305 | 1212 × 219 mm | DN125(5") | GHO1148T5L/4P | 120 W × 6 | QT5-1183 | ZUM3-800-120 |
SB10-H07 | 80 | 355 | 1212 × 219 mm | DN125(5") | GHO1148T5L/4P | 120 W × 7 | QT5-1183 | ZUM3-800-120 |
SB10-HA3 | 105 | 465 | 1618 × 219 mm | DN150(6") | GPHHA1554T6L | 320 W × 3 | QT6-1589 | ZUM4-2100-320 |
SB10-HA4 | 137 | 605 | 1618 × 219 mm | DN150(6") | GPHHA1554T6L | 320 W × 4 | QT6-1589 | ZUM4-2100-320 |
SB10-HA5 | 168 | 740 | 1618 × 219 mm | DN150(6") | GPHHA1554T6L | 320 W × 5 | QT6-1589 | ZUM4-2100-320 |
SB10-HA6 | 198 | 870 | 1618 × 219 mm | DN150(6") | GPHHA1554T6L | 320 W × 6 | QT6-1589 | ZUM4-2100-320 |
SB10-HA7 | 298 | 1315 | 1618 × 274 mm | DN200(8") | GPHHA1554T6L | 320 W × 7 | QT6-1589 | ZUM4-2100-320 |
SB10-HA8 | 337 | 1485 | 1618 × 274 mm | DN200(8") | GPHHA1554T6L | 320 W × 8 | QT6-1589 | ZUM4-2100-320 |
SB10-HA9 | 459 | 2021 | 1618 × 325 mm | DN250(10") | GPHHA1554T6L | 320 W × 9 | QT6-1589 | ZUM4-2100-320 |
SB10-HA10 | 505 | 2225 | 1618 × 325 mm | DN250(10") | GPHHA1554T6L | 320 W × 10 | QT6-1589 | ZUM4-2100-320 |
Specifications
Model | Flow Rate | Reactor Dimension | In/Outlet Port BSP/NPT |
UV Lamp Code | Lamp Power | Quartz Tube Code | Ballast Code | |
---|---|---|---|---|---|---|---|---|
m3 /hr | GPM | |||||||
SA-3120 | 35 | 155 | 1420 × 168 mm | DN80(3") | GHO1148T5L/4P | 120 W × 3 | QT6-1183 | ZUM3-800-120 |
SA-4120 | 45 | 200 | 1420 × 219 mm | DN100(4") | GHO1148T5L/4P | 120 W × 4 | QT6-1183 | ZUM3-800-120 |
SA-5120 | 55 | 245 | 1420 × 219 mm | DN125(5") | GHO1148T5L/4P | 120 W × 5 | QT6-1183 | ZUM3-800-120 |
SA-6120 | 70 | 310 | 1420 × 274 mm | DN150(6") | GHO1148T5L/4P | 120 W × 6 | QT6-1183 | ZUM3-800-120 |
SA-7120 | 80 | 355 | 1420 × 274 mm | DN150(6") | GHO1148T5L/4P | 120 W × 7 | QT6-1183 | ZUM3-800-120 |
SA-8120 | 95 | 420 | 1420 × 274 mm | DN200(8") | GHO1148T5L/4P | 120 W × 8 | QT6-1183 | ZUM3-800-120 |
SA-9120 | 120 | 530 | 1420 × 325 mm | DN200(8") | GHO1148T5L/4P | 120 W × 9 | QT6-1183 | ZUM3-800-120 |
Specifications
Table 3:SBA Series | ||||||||
Model | Flow Rate | Reactor Dimension | In/Outlet Port BSP/NPT |
UV Lamp Code | Lamp Power | Quartz Tube Code | Ballast Code | |
---|---|---|---|---|---|---|---|---|
m3/hr | GPM | |||||||
SBA10-4320 | 120 | 530 | 1665 × 219 mm | DN125(5") | GPHHA1554T6L | 320 W × 4 | QT6-1630 | ZUM4-2100-320 |
SBA10-5320 | 150 | 660 | 1665 × 219 mm | DN150(6") | GPHHA1554T6L | 320 W × 5 | QT6-1630 | ZUM4-2100-320 |
SBA10-6320 | 230 | 1012 | 1665 × 274 mm | DN200(8") | GPHHA1554T6L | 320 W × 6 | QT6-1630 | ZUM4-2100-320 |
SBA10-8320 | 300 | 1320 | 1665 × 274 mm | DN250(10") | GPHHA1554T6L | 320 W × 8 | QT6-1630 | ZUM4-2100-320 |
SBA10-10320 | 450 | 1980 | 1665 × 325 mm | DN300(12") | GPHHA1554T6L | 320 W × 10 | QT6-1630 | ZUM4-2100-320 |
SBA10-12320 | 530 | 2335 | 1665 × 325 mm | DN300(12") | GPHHA1554T6L | 320 W × 12 | QT6-1630 | ZUM4-2100-320 |
Water Quality Requirements
Specifications
Model | Reactor Dimension | Reactor Dimension | In/Outlet Port BSP/NPT |
Package Size cm | UV Lamp Code | Lamp Power | Quartz Tube Code | Ballast Code | |
---|---|---|---|---|---|---|---|---|---|
Reactor Dimension | |||||||||
SIB-187 | 5.4 | 24 | 885 × 89 mm | 1" male | 102.5 × 22.4 × 42 / 1 set | UVT5-487 | 87 W × 1 | QT5-875 | ZAP3 |
SIB-287 | 10 | 53 | 885 × 108 mm | 1" male | 102.5 × 22.4 × 42 / 1 set | UVT5-487 | 87 W × 2 | QT5-875 | ZAP3 |
SIB-387 | 18 | 97 | 885 × 133 mm | 1.5" male | 102.5 × 24.8 × 45 / 1 set | UVT5-487 | 87 W × 3 | QT5-875 | ZAP3 |
SIB-487 | 24 | 132 | 885 × 133 mm | 1.5" male | 102.5 × 24.8 × 45 / 1 set | UVT5-487 | 87 W × 4 | QT5-875 | ZAP3 |
SIB-587 | 37 | 163 | 885 × 168 mm | 2" male | 107.0 × 35.0 × 60 /1 set | UVT5-487 | 87 W × 5 | QT5-875 | ZAP3 |
SIB-687 | 45 | 198 | 885 × 168 mm | 2" male | 107.0 × 35.0 × 60 / 1 set | UVT5-487 | 87 W × 6 | QT5-875 | ZAP3 |
SIB-787 | 60 | 230 | 885 × 217 mm | 3" male | 107.0 × 40.0 × 70 / 1 set | UVT5-487 | 87 W × 7 | QT5-875 | ZAP3 |
SIB-887 | 67 | 264 | 885 × 217 mm | 3" male | 107.0 × 40.0 × 70 / 1 set | UVT5-487 | 87 W × 8 | QT5-875 | ZAP3 |
Water Quality Requirements
Specifications
Model | Flow Rate | Reactor Dimension | In/Outlet Port BSP/NPT |
Package Size cm | UV Lamp Code | Lamp Power | Quartz Tube Code | Ballast Code | |
---|---|---|---|---|---|---|---|---|---|
m3/hr | GPM | ||||||||
SIBM-2120 | 14 | 61 | 1212 × 108 mm | DN50 | 140 × 20 × 45 / 1 set | UVT5-4120 | 120 W × 2 | QT5-1183 | ZUM3-800-120 |
SIBM-3120 | 35 | 154 | 1212 × 133 mm | DN65 | 140 × 24 × 48 / 1 set | UVT5-4120 | 120 W × 3 | QT5-1183 | ZUM3-800-120 |
SIBM-4120 | 45 | 198 | 1212 × 133 mm | DN80 | 140 × 24 × 48 / 1 set | UVT5-4120 | 120 W × 4 | QT5-1183 | ZUM3-800-120 |
SIBM-5120 | 55 | 242 | 1212 × 168 mm | DN80 | 140 × 28 × 50 / 1 set | UVT5-4120 | 120 W × 5 | QT5-1183 | ZUM3-800-120 |
SIBM-6120 | 70 | 308 | 1212 × 168 mm | DN100 | 140 × 28 × 50 / 1 set | UVT5-4120 | 120 W × 6 | QT5-1183 | ZUM3-800-120 |
SIBM-7120 | 80 | 352 | 1212 × 219 mm | DN100 | 140 × 33 × 56 / 1 set | UVT5-4120 | 120 W × 7 | QT5-1183 | ZUM3-800-120 |
SIBM-8120 | 95 | 418 | 1212 × 219 mm | DN125 | 140 × 33 × 56 / 1 set | UVT5-4120 | 120 W × 8 | QT5-1183 | ZUM3-800-120 |
SIBM-9120 | 100 | 440 | 1212 × 275 mm | DN125 | 140 × 38 × 62 / 1 set | UVT5-4120 | 120 W × 9 | QT5-1183 | ZUM3-800-120 |
SIBM-10120 | 115 | 506 | 1212 × 275 mm | DN150 | 140 × 38 × 62 / 1 set | UVT5-4120 | 120 W × 10 | QT5-1183 | ZUM3-800-120 |
Specifications
Model | Flow | Lamp Power | Lamp Life | Inlet/Output |
---|---|---|---|---|
SMP108 A1/2 | 15 m3/hr | 0.6 kW | 8000 hours | DN50(2") |
SMP108 B1/2 | 30 m3/hr | 1.1 kW | 8000 hours | DN50(2") |
SMP168 B1/2 | 50 m3/hr | 1.1 kW | 8000 hours | DN50(2") |
SMP168 C1/3 | 60 m3/hr | 2.1 kW | 8000 hours | DN80(3") |
SMP108 C1/4 | 100 m3/hr | 2.1 kW | 8000 hours | DN100(4") |
SMP168 D1/4 | 100 m3/hr | 3.4 kW | 8000 hours | DN100(4") |
SMP219 C1/4 | 100 m3/hr | 2.1 kW | 8000 hours | DN100(4") |
SMP219 D1/6 | 230 m3/hr | 3.4 kW | 8000 hours | ON150(6") |
SMP325 D1/8 | 350 m3/hr | 3.4 kW | 8000 hours | DN200(8") |
SMP325 E1/8 | 400 m3/hr | 4.9 kW | 8000 hours | DN200(8") |
SMP325 E1/10 | 535 m3/hr | 4.9 kW | 8000 hours | DN250(10") |
Ultraviolet sterilization is a disinfection technology based on modern epidemiology, optics, biology and physical chemistry. It utilizes a UV-C emitting device to irradiate water flow with UV-C light. When various bacteria, viruses, parasites, algae, and other pathogens in the water are exposed to a certain dose of UV-C radiation, the DNA (deoxyribonucleic acid) or RNA (ribonucleic acid) structure within their cells is damaged, causing them to lose the ability to replicate and reproduce. Since the lifecycle of bacteria and viruses is generally short, those unable to reproduce will quickly die. Thus, the sterilization and disinfection effect is achieved without the use of any chemical agents.
Here are product catalogue and data sheet for your reference. more information just contact us.