How to Choose the Right Water Distributor Quickly?

Water distributor is generally installed inside FRP tanks, featuring uniform water distribution and low flow rate. You can choose the right water distributor based on your FRP tank sizes. You may follow the following steps to choose the right water distributor, to extend the lifespan of water distributor, improve the working efficiency of filtration or softening and save the costs.

FRP Tank Diameter.

You may choose the FRP tank size based on the desired flow rate of FRP tanks. According to the formula, Q = πr2*V = π(D/2)2 V, it can be concluded that FRP tank diameter D2 = 4*Q/(πV). Generally, the softening flow rate V is 20 m/h and filtration flow rate V is10–20 m/h.

Diameter

You may choose the FRP tank size based on the desired flow rate of FRP tanks. According to the formula, Q = πr2*V = π(D/2)2 V, it can be concluded that FRP tank diameter D2 = 4*Q/(πV). Generally, the softening flow rate V is 20 m/h and filtration flow rate V is10–20 m/h.

Water Distributor Selection

FRP tanks are generally provided with an upper port or an upper port & a lower port. FRP tanks with an upper port generally require a central pipe for connection when installing a water distributor. Multiport control valves are installed at the top of FRP tanks and the upper port is made of reinforced PPO modified plastic materials; FRP tanks with an upper port & a lower port require no central pipe for connection when installing a water distributor. Multiport control valve is installed on the sides of FRP tanks and the upper & lower ports are made of reinforced PPO modified plastic materials with flange connection.

Product FRP Tanks Water Distributor
No. FRP Tank Size Multiport Control Valve Installation Position Upper Port Lower Port Upper Distributor Lower Distributor
1 6"–16" (150 mm – 400 mm) Top-mounted 2.5" F0601 F0602
F0603CW F0604CW
F0611 F0612
F0613CW F0614CW
2 10"–16" (250 mm– 400 mm) Top-mounted 4" F182/F182L F182X/FU6260/FU6260B
18"–21" (450 mm– 550 mm) Top-mounted 4" F182/F182L F182X/FU6370/FU6370B
24" (600 mm) Top-mounted 4" F182/F182L F182X/FU6450/FU6450B
30" (750 mm) Top-mounted 4" F182/F182L F182X/FU6600/FU6600B
36" (900 mm) Top-mounted 4" F182/F182L F182X/FU6700/FU6700B
40"(1000 mm) Top-mounted 4" F182/F182L F182X/FU6800/FU6800B
3 10"–16" (250 mm – 400 mm) Side-mounted 4" 4" F5671/F5672 FD6260/F11036
18"–21" (450 mm – 550 mm) Side-mounted 4" 4" F5671/F5672 FD6370/F11037
24" (600 mm) Side-mounted 4" 4" F5671/F5672 FD6450/F11038
30" (750 mm) Side-mounted 4" 4" F5671/F5672 FD6600/F11039
36" (900 mm) Side-mounted 4" 4" F5671/F5672 FD6700/F11040
40" (1000 mm) Side-mounted 4" 4" F5671/F5672 FD6800/F11041
4 30" (750 mm) Side-mounted 6" flange 6" flange F173/ F175 FD5672/FD5672-2
36" (900 mm) Side-mounted 6" flange 6" flange F173/F175 FD5673/FD5673-2
40"–42" ( 1000 mm) Side-mounted 6" flange 6" flange F173/F175 FD5674/FD5674-2
48" (1200 mm) Side-mounted 6" flange 6" flange F173/F175 FD5675/FD5675-2
56"–65" (1400 mm – 1600 mm) Side-mounted 6" flange 6" flange F173/F175 FD5676/FD5676-2
65"–80" (1600 mm –2000 mm) Side-mounted 6" flange 6" flange F173/F175 FD5678/FD5678-2